TEST

 0    45 fiche    jakubglowala8
ladda ner mp3 skriva ut spela Kontrollera dig själv
 
Fråga English Svar English
during an HYD2 system loss, the PTU can still be used to lower the landing gear if:
börja lära sig
there's minimum hydraulic quantity of 12% in the right reservoir
wingspan of emb170 and emb190
börja lära sig
26m and 28,72m
Where is located the waste tank servicing panel:
börja lära sig
on the rear right side of fuselage
dump switch button - what will happen after press in
börja lära sig
ECS packs, recirculation fans to OFF. depressurize the cabin to 12400ft
How many channels does the cabin pressurization controller have
börja lära sig
2
Where are installed the two ECS packs?
börja lära sig
wing to fuselage fairing
APU model
börja lära sig
Sunstrand APS 2300
How many inverters are in the aircraft?
börja lära sig
1
What IDG 1 and IDG 2 normally power?
börja lära sig
IDG 1 - AC BUS 1 and IDG 2 - AC BUS 2
T2 sensor
börja lära sig
monitors the engine air inlet temperature
N1 sensor
börja lära sig
provides the fan speed data for FADEC and vibration monitoring system
How many multi-function spoilers are on each wing?
börja lära sig
5: 3 outboard and 2 inboard
How long will de-icing system remain on after icing is no longer detected?
börja lära sig
5 minutes
The accumulator of emergency parking brake have sufficient pressure to provide:
börja lära sig
6 full-brake applications
EGPWS: High-density red dots indicate:
börja lära sig
terrain more than 2000ft above airplane altitude
What happened during pushback if speed will be higher than set and hydraulic systems 1 and 2 will be depressurized?
börja lära sig
there will be EICAS message BRK LH (RH) FAULT or FAIL
the APU will automatically shutdown in flight if the following occur:
börja lära sig
overspeed, underspeed, FADEC critical fault
What is the maximum continuous temperature for engine?
börja lära sig
960°C
the navigation data base is updated every:
börja lära sig
28 days
inertial reference system (IRS) computes:
börja lära sig
airplane position, ground speed, heading and attitude
When is the wind shear detection activated?
börja lära sig
between 10 and 1500ft
TRU ESS provides DC power to:
börja lära sig
DC ESS BUS 3
Which ADSP will be heated when the batteries are the only electrical source?
börja lära sig
ADSP 3
When the TCAS automatically reverts to TA only mode?
börja lära sig
belów 900ft AGL during descent, or below 1100ft during climb
How long does the IESS take for alignment?
börja lära sig
90 seconds
How many electrical sensors measure the fuel quantity?
börja lära sig
13 in each tank
ILS covergae
börja lära sig
10° to 25nm and 35° to 17nm
MEL - interval repair indication: A B C D
börja lära sig
A - no standard, B - 3 days, C - 10 days, D - 120 days
What is included in the fire protection system (4 items)?
börja lära sig
Engines, APU, Cargo compartments, lavatories
What happens when you pull the fire extinguisher handle? (4 items)
börja lära sig
fuel, hydraulic, bleed air and crossbleed shutoff valves close
The fire handle illumination went off after discharging the bottle, but the EICAS warning ENG FIRE is still active. Is the fire still present?
börja lära sig
Yes
What happens during detection of smoke in the lavatory (4 items)?
börja lära sig
Master warning, EICAS warning - LAV SMOKE, alarm sound and light in the lavatory, flashing ORANGE light on rainbow lights
What happen if you press fire detection test buttom for more than 10s?
börja lära sig
the APU will shut down
What does the AP quick disconnect button do?
börja lära sig
disconnects the autopilot and stops any active trim command
Flaps/slats - sequence of deployment.
börja lära sig
slats extend first and flaps retracts first
What happens in the intermediate position of flap/slat lever?
börja lära sig
flaps/slats remain in the last selected position
What will happen if the CPT and F/O operate the control wheel pitch trim in the opposite direction?
börja lära sig
captain has priority
What will happen if PBIT expires in flight?
börja lära sig
no action is required
Total electricity loss - may we still operate flight controls?
börja lära sig
yes, for at least 15 minutes through the backup power system
ETC, PCU, AFU - what do these acronyms stand for?
börja lära sig
ETC - elevator thrust compensation. PCU - power control unit. AFU - artificial feel units
Strike overload - how many attempts are possible?
börja lära sig
2 attempts
Slats/flaps and RAT deployed - does anything change?
börja lära sig
the flap and slat operate in half speed. And max position 3
LOW1 in dual eng fail - why?
börja lära sig
AC ESS BUS powers the AC Fuel PUMP 2A
Dripstick - what is it used for?
börja lära sig
provide an alternate means for fuel measuring (mounted under each wing)
Ejector fuel pump - from which electrical bus is it fed?
börja lära sig
it does not require electrical power to operate